Re: ISDN and Ascend 4K

Kurt Schafer ( (no email) )
Sun, 20 Jul 1997 18:05:03 -0400

I'm assuming you want to use MPP because the caller dialing in is using an
Ascend Pipeline ?

Contrary to popular belief, MPP does not stand for multilink-PPP. I've
never had any problems getting multilink working using type=PPP in the
RADIUS profile. You might also want to try adding in an
Ascend-Maximum-Channels =2 in the profile in case it's defaulting to 1 B
channel only for whatever reason.

Also, if you have multiple Max4000's, make sure Stacking is turned on in
the Ethernet settings to allow multiple B channels to connect across
multiple maxes.

- Kurt
----------
> From: Brad Jenkins <brad@jps.net>
> To: 'radiusnt@iea.com'
> Subject: ISDN and Ascend 4K
> Date: Sunday, July 20, 1997 5:14 PM
>
> Having a problem with Radius auth for ISDN accounts trying to get Dual B
MPP assigned. When I add the users into "Ethernet" Connections, there is
not a problem, but when I try to have the profile in the Radius use MPP,
the account is rejected each time. Any idea's?
>
> Thanks,
> Brad Jenkins
>
> Example:
>
> 1111111 Password="1111111"
> User-Service-Type=Framed-User,
> Framed-Address=255.255.255.254,
> Framed-Protocol=MPP
>
> ----------------------------------------------------------
> RadiusNT Mailing List listserver@emerald.iea.com
>