Re: [NTISP] Rockwell

( " )
Tue, 9 Mar 1999 13:13:02 -0600

is this an init string for the customers modem? or something set on the
ascend max..

Ken
-----Original Message-----
From: Youssef A. Rahman <yrahman@alexcomm.net>
To: ntisp@iea-software.com <ntisp@iea-software.com>
Date: Tuesday, March 09, 1999 1:11 PM
Subject: Re: [NTISP] Rockwell

>We had the same problem with the Ascend Max, and the following
>initialization string stopped it
>+ms=k56,1,75,33600,75,5600
>
>
>"Geoffrey L. Scully" wrote:
>
>> I am having problems with Rockwell V.90's and most Win Modems with the
>> 3COM Hiper DSP's. They sit there continuing to handshake and then
>> eventually timeout. Anyone else having this problem? Anyone figure out
>> the fix?
>>
>> For more information about this list, including removal,
>> see this url: http://www.iea-software.com/maillist.html
>
>
>For more information about this list, including removal,
>see this url: http://www.iea-software.com/maillist.html

For more information about this list, including removal,
see this url: http://www.iea-software.com/maillist.html