RE: [NTISP] Port Density

Fernando M. Kiernan ( (no email) )
Fri, 5 Mar 1999 10:24:12 -0300

Goeffrey:
We are at 4.1.59 level and setting the port density to 30 in our case =
(we use E1) works well.
The commands are:
SET PBUS REPORTED_BASE 1
SET PBUS REPORTED PORT_DENSITY XX (23,24 or 30, that fits your needs)
SAVE ALL
REBOOT

The reboot is important, in our case the changes not showed upto the =
reboot.

Hope this helps

Fernando M. Kiernan
DILHARD S.A.
fkiernan@dilhard.com.ar
http://www.dilhard.com.ar

-----Original Message-----
From: ntisp-request@iea-software.com
[mailto:ntisp-request@iea-software.com]On Behalf Of Geoffrey L. Scully
Sent: Thursday, March 04, 1999 11:35 PM
To: ntisp@iea-software.com
Subject: [NTISP] Port Density

How do you change the Hiper ARC to read 0-# for ports instead of the
crazy way 3COM has it by default?

For more information about this list, including removal,
see this url: http://www.iea-software.com/maillist.html

For more information about this list, including removal,
see this url: http://www.iea-software.com/maillist.html