Re: [NTISP] Total control DSP modem problem

Geoffrey L. Scully ( (no email) )
Wed, 24 Feb 1999 11:32:49 -0800

--------------E1F865F376CAF5F0B49B4240
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit

Yep, that could certainly be so. I will try it on one of mine that is
in service and see if it makes a difference.

Carolyn Smith wrote:

> That gave me the message that it cannot change ports of a dynamic
> entry. Just a question. Should is disable this slot from service
> while I do this? Could that be why I'm getting this message?
>
> ----- Original Message -----
> From: Geoffrey L. Scully
> To: ntisp@iea-software.comSent: Wednesday, February 24, 1999
> 2:11 PMSubject: Re: [NTISP] Total control DSP modem problem
> Try just this.
> set chassis slot "#" ports 24
>
> Carolyn Smith wrote:
>
> > It's telling me that it cannot change a card type of a
> > dynamic entry
> >
> > ----- Original Message -----
> > From: Geoffrey L. Scully
> > To: ntisp@iea-software.comSent: Wednesday,
> > February 24, 1999 2:03 PMSubject: Re: [NTISP]
> > Total control DSP modem problem
> > Let me know if this does not work and I will
> > try and see why not.
> >
> > Carolyn Smith wrote:
> >
> > > Thanks abunch.Carolyn
> > >
> > > ----- Original Message -----
> > > From: Geoffrey L. Scully
> > > To: ntisp@iea-software.comSent:
> > > Wednesday, February 24, 1999 1:49
> > > PMSubject: Re: [NTISP] Total control
> > > DSP modem problem
> > > Just Telnet in.
> > >
> > > Carolyn Smith wrote:
> > >
> > > > Were do I enter this command at.
> > > > In the TCM or do I use the console
> > > > method. Carolyn
> > > >
> > > > ----- Original Message
> > > > -----
> > > > From: Geoffrey L. Scully
> > > > To:
> > > > ntisp@iea-software.comSent:
> > > > Wednesday, February 24,
> > > > 1999 1:35 PMSubject: Re:
> > > > [NTISP] Total control DSP
> > > > modem problem
> > > > set chassis slot "#"
> > > > type hdm_24 owner yes
> > > > ports 24
> > > >
> > > > This makes sure the
> > > > particular slot is set up
> > > > for Hiper DSP 24 ports
> > > >
> > > > Carolyn Smith wrote:
> > > >
> > > > > Hello, I have one USR
> > > > > Total Control unit with
> > > > > 4 Hiper dsp cards(nodem
> > > > > cards) installed. The
> > > > > fourth card was the
> > > > > last installed and it
> > > > > has given us problems
> > > > > ever since. I had the
> > > > > card replaced but the
> > > > > problem is still
> > > > > somewhat there. The
> > > > > problem is that one of
> > > > > the modems (#24) has
> > > > > not been used since we
> > > > > installed the card. It
> > > > > is also returning the
> > > > > error of "pk bus
> > > > > generic error" in the
> > > > > TMC as the reason for
> > > > > call failure. I
> > > > > thought it might be
> > > > > because I use
> > > > > Channelized t1's but
> > > > > all the other cards
> > > > > modems never return
> > > > > this error. I also
> > > > > checked in my Hiper Arc
> > > > > Router mgr. software
> > > > > and found that the
> > > > > modem card is only
> > > > > returning 23 modems as
> > > > > being up. Does anyone
> > > > > out there use this same
> > > > > equipment and have any
> > > > > ideal what could be
> > > > > causing this problem?
> > > > > ThanksC. Smith
> > > >

--------------E1F865F376CAF5F0B49B4240
Content-Type: text/html; charset=us-ascii
Content-Transfer-Encoding: 7bit

<!doctype html public "-//w3c//dtd html 4.0 transitional//en">
Yep, that could certainly be so.  I will try it on one of mine thatis in service and see if it makes a difference.

Carolyn Smith wrote:

 That gave me the message thatit cannot change ports of a dynamic entry. Justa question.  Should is disable this slot from service while I do this? Could that be why I'm getting this message? 
----- Original Message -----
From: GeoffreyL. Scully
To: ntisp@iea-software.comSent:Wednesday, February 24, 1999 2:11 PMSubject: Re: [NTISP] Total controlDSP modem problem
 Try just this.
set chassis slot "#" ports 24

Carolyn Smith wrote:

 It's telling me that it cannotchange a card type of a dynamic entry
----- Original Message -----To: ntisp@iea-software.comSent:Wednesday, February 24, 1999 2:03 PMSubject: Re: [NTISP] Total controlDSP modem problem
 Let me know if this does not work and I will try and see why not.

Carolyn Smith wrote:

 Thanks abunch.Carolyn
----- Original Message -----To: ntisp@iea-software.comSent:Wednesday, February 24, 1999 1:49 PMSubject: Re: [NTISP] Total controlDSP modem problem
 Just Telnet in.

Carolyn Smith wrote:

 Were do I enter this commandat.  In the TCM or do I use the console method. Carolyn
----- Original Message -----To: ntisp@iea-software.comSent:Wednesday, February 24, 1999 1:35 PMSubject: Re: [NTISP] Total controlDSP modem problem
 set chassis slot "#" type hdm_24 owner yes ports 24

This makes sure the particular slot is set up for Hiper DSP 24 ports

Carolyn Smith wrote:

Hello, Ihave one USR Total Control unit with 4 Hiper dsp cards(nodem cards) installed.The fourth card was the last installed and it has given usproblems ever since.  I had the card replaced but the problem is stillsomewhat there.  The problem is that one of the modems (#24) has notbeen used since we installed the card.  It is also returning the errorof "pk bus generic error" in the TMC as the reason for call failure. I thought it might be because I use Channelized t1's but all the othercards modems never return this error. I also checkedin my Hiper Arc Router mgr. software and found that the modem card is onlyreturning 23 modems as being up. Does anyone out thereuse this same equipment and have any ideal what could be causing this problem?ThanksC. Smith