Re: [NTISP] Total control DSP modem problem

Carolyn Smith ( (no email) )
Wed, 24 Feb 1999 13:41:27 -0500

This is a multi-part message in MIME format.

------=_NextPart_000_000D_01BE5FFB.607C9540
Content-Type: text/plain;
charset="Windows-1252"
Content-Transfer-Encoding: quoted-printable

Were do I enter this command at. In the TCM or do I use the console =
method.

Carolyn
----- Original Message -----=20
From: Geoffrey L. Scully=20
To: ntisp@iea-software.com=20
Sent: Wednesday, February 24, 1999 1:35 PM
Subject: Re: [NTISP] Total control DSP modem problem

set chassis slot "#" type hdm_24 owner yes ports 24=20
This makes sure the particular slot is set up for Hiper DSP 24 ports=20

Carolyn Smith wrote:=20

Hello, I have one USR Total Control unit with 4 Hiper dsp =
cards(nodem cards) installed. The fourth card was the last installed and =
it has given us problems ever since. I had the card replaced but the =
problem is still somewhat there. The problem is that one of the modems =
(#24) has not been used since we installed the card. It is also =
returning the error of "pk bus generic error" in the TMC as the reason =
for call failure. I thought it might be because I use Channelized t1's =
but all the other cards modems never return this error. I also checked =
in my Hiper Arc Router mgr. software and found that the modem card is =
only returning 23 modems as being up. Does anyone out there use this =
same equipment and have any ideal what could be causing this problem? =
ThanksC. Smith

------=_NextPart_000_000D_01BE5FFB.607C9540
Content-Type: text/html;
charset="Windows-1252"
Content-Transfer-Encoding: quoted-printable

<!DOCTYPE HTML PUBLIC "-//W3C//DTD W3 HTML//EN">

Were do I enter this command at.  In the TCM or =do I use=20the console method.
 
Carolyn
----- Original Message -----=20
From: Geoffrey L. =Scully=20
To: ntisp@iea-software.com
Sent: Wednesday, February 24, 1999 1:35 PM
Subject: Re: [NTISP] Total control DSP modem =problem

set chassis slot "#" type hdm_24 owner yes =ports 24=20

This makes sure the particular slot is set up for Hiper DSP 24 =ports=20

Carolyn Smith wrote:=20

Hello, I have one USR =Total Control=20 unit with 4 Hiper dsp cards(nodem cards) =installed. The fourth card was the last installed and it has given us =problems=20 ever since.  I had the card replaced but the problem is still =somewhat=20 there.  The problem is that one of the modems (#24) has not =been used=20 since we installed the card.  It is also returning the error of = "pk bus generic error" in the TMC as the reason for call=20 failure.  I thought it might be because I use Channelized t1's =but all=20 the other cards modems never return this error. I=20 also checked in my Hiper Arc Router mgr. software and found that the =modem=20 card is only returning 23 modems as being up. Does=20 anyone out there use this same equipment and have any ideal what =could be=20 causing this problem? ThanksC. Smith
------=_NextPart_000_000D_01BE5FFB.607C9540--