Kurt Schafer wrote:
>
> How would I go about setting up Emerald/RadiusNT to handle a Portmaster 4 with 2 Quad T1 cards.
>
> I upgraded to the latest 4.23b code cause I heard there was an issue with port numbering in the older revisions but how are the ports numberred now ?
>
> I have 192 ports in the thing.

Took me a while to find this:

The forthcoming ComOS 4.1 fixes the port numbering for RADIUS. The
port number will break down like this:

2 bits shelf number (settable by user, eventually may expand to 18
bits)
4 bits slot number
5 bits line (to allow future expansion)
5 bits channel

So every port will have a unique number, and as port densities grow the
same numbering scheme can continue to be used.

-- 

Dale E. Reed Jr. Emerald and RadiusNT__________________________________________IEA Software, Inc. www.iea-software.com