Re: [RadiusNT] No pwd in request!

Dale E. Reed Jr. ( (no email) )
Mon, 07 Jun 1999 13:14:28 -0500

David McMullen wrote:
>
> I have a cisco 3640 authenticating against radiusNT 2.5.175.
>
> Authentication of analog connections and telnet connections is working fine,
> but when I try an ISDN connection using NT4.0 dialup networking the
> authentication is being rejected with the following error:

You need to include the full -x15 debug, for us to interupt this.
Sounds like its probably a bug in the Cisco, though. You might
check to see if there is a later update for it.

> Authenticate: from 192.168.4.2 - No pwd in request!
>
> I also get a Received unknown attribute 11, vendor 311 error as part of the
> same request.

This is just a VSA attribute. Not sure who Vendor 311 is? (Cisco
is 9).

-- 

Dale E. Reed Jr. Emerald and RadiusNT__________________________________________IEA Software, Inc. www.iea-software.com