Re: frequent disconnects

Josh Hillman ( (no email) )
Wed, 17 Jun 1998 18:47:12 -0400

> From: Jason Chimney <jason@cnx.net>
> Sorry for sounding stupid, but where exactly to I change these settings?
I
> am using the MS Access ODBC database.

In the Max:
Ethernet --> Answer --> Session Options
Idle=(value measured in seconds) --- I accidentally mentioned
"1200 = 2 mins" in my previous
message. Ascend defaults
to 120 seconds = 2 minutes.
Ethernet --> Connections --> (whatever) --> Session Options
Idle=(value measured in seconds)

I don't know how it's set in Radius attributes for Access (we're using
SQL).

Josh Hillman
hillman@talstar.com

> -----Original Message-----
> From: Josh Hillman <admin-maillist@talstar.com>
> To: radiusnt@iea-software.com <radiusnt@iea-software.com>
> Date: Wednesday, June 17, 1998 10:59 AM
> Subject: Re: frequent disconnects
>
>
> >> From: jason@cnx.net
> >> Hi, does anyone have any ideas why more than a few of our dial up
> >customers
> >> are getting disconnected (some say every couple minutes)?
> >> We are running ascend max 4004 boxes.
> >
> >Chances are your Ascend-Idle-Limit Radius attribute is set too low,
and/or
> >your default Idle timeout settings in the Max are set to low (they're
set
> >at 1200 seconds (2 minutes) from the factory. What do your accounting
stop
> >records say for the "Ascend-Disconnect-Cause"?
> >
> >Josh Hillman
> >hillman@talstar.com
> >
> >