ODBC Error:23000:-1053: Primary key cant contain null value

Jorge Pocaterra ( (no email) )
Tue, 19 May 1998 13:22:47 -0400

Hi Dale

i'm running radiusNT 2.5.107 with a Computone PowerRack and a USR
Totalcontrol, now everithing is running well with the Totalcontrol but when
radius receives the stop record from the computone it gives me the following
error

ODBC Error:23000:-1053:
[Microsoft][ODBC Microsoft access 97 driver] Index or index or primary key
cant contain null value

What could be wrong with the data base?

I had the Powerrack working on an other radius server runing RadiusNT 1.49
and it was working well.

Thanks in advance

Jorge Pocaterra T.
Junior@enlared.net