Re: On the Bleeding Edge again

Dale E. Reed Jr. ( (no email) )
Thu, 08 Jan 1998 11:15:12 -0800

Brian Lube wrote:
>
> We're working with a new USR HiPerARC access router here, and I've gotten it
> to authenticate, but for some reason I'm not getting any entries into
> callsonline. I'm including at the bottom of this two entries from the
> radius server (in terminal mode). Has anyone else seen other equipment work
> like this (has proper radius settings and is being put into calls, but not
> callsonline)?

The error means "we've seen this record already". This is a
re-transmit of the record (most likely) since the Acct-Delay-Time
is non-zero. Check your response times on the original request,
and also check the timeout value of the NAS (if its modifiable)
and set it to a highe value.

> Resp Time: 10 Auth: 7/1 -> 8 Acct: 6/238/3 -> 247
> radrecv: Request from host d006c705 code=4, id=21, length=277
> User-Name = "rlee"
> NAS-Identifier = 208.6.199.5
> Acct-Status-Type = Stop
> Acct-Session-Id = "17000301"
> Acct-Delay-Time = 60
> Acct-Authentic = RADIUS
> User-Service = Framed-User
> NAS-Port = 52
> Caller-Id = "4078340213"
> NAS-Port-DNIS = "4751041"
> Framed-Protocol = PPP
> Framed-Address = 208.6.199.13
> Acct-Session-Time = 51
> Acct-Terminate-Cause = User-Request
> Acct-Input-Octets = 1005
> Acct-Output-Octets = 372
> Acct-Input-Packets = 46
> Acct-Output-Packets = 15
>
> ODBC: SQLExecDirect Error 2627:
> [Microsoft][ODBC SQL Server Driver][SQL Server]Violation of PRIMARY KEY
> constraint 'pk_Calls': Attempt to insert duplicate key in object 'Calls'.
> Sending Accounting Ack of id 21 to d006c705 (hiper1.mpinet.net)

-- Dale E. Reed Jr.  (daler@iea.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |   http://www.iea-software.com