Re: Server Ports for the Max

Mitchell B. Wagers ( (no email) )
Fri, 19 Dec 1997 15:17:44 -0800

Here's the stuff...
Analog - Async calls are 20 - Line# - Chan#, so you would have 20101 for
port 1 async, they go from 20101 to 20124, then the next line, 20201 and so
on....
ISDN are 10NXX, so port 1 ISDN would be 10101.

At 04:38 PM 12/19/97 -0600, you wrote:
>PLEASE don't flame me. I am new to RadiusNT. I have it working fine in
>ODBC mode. However, I do have one problem. I can not get RadiusNT to do
>accounting, I feel that my "Server Ports" table is not set up correctly. I
>have an Ascend Max 4048. The server port table asks for server ID which is
>1-for my ascend box, then it asks for Port and IP address. I have no ideal
>what the prots are (dont know how to find out) and I assign IP address from
>a Pool. Any help will be GREATLY appreciated as I need to know how long
>people are being connected each month.
>
>
>
>Thanks,
>John Chalker
>CyberSouth Internet Comm., Inc.
>http://www.cyber-south.com
>root@cyber-south.com
>
> ----------------------------------------------------------
> RadiusNT Mailing List lists@iea-software.com
>
>