(no subject)

Dale E. Reed Jr. ( (no email) )
Wed, 23 Jul 1997 14:00:18 -0700

Chuck Neville wrote:
>
> When I try to use Radlogin to test my RadiusNT installation, I get the
> following:
>
> Checking Radius user test:
>
> (null): couldn't open /radius/server to find server
>
> I am running this in ODBC mode and all the sample databases are
> installed.

You need to create a file called "server" that is in the
same format as the clients file. Radlogin will read the first
line of this file for the server and secret to send the request
to.

See changes.txt on radlogin for more details on this.

-- Dale E. Reed Jr.  (daler@iea.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |    http://www.emerald.iea.com