Max Time-Out Values

Scott Lagos ( slagos@net1plus.com )
Mon, 10 Mar 1997 06:57:25 -0500

Dale,

What is the largest Idle-Time Out and Session-Time Out number that can be
placed in the RadConfigs table? I have tried putting in 12 hours
represented in seconds, but when I do a radlogin I get a negative amount
(the difference from the value and 65536 if the value is greater than
32767). What entry should I put in for No Idle Time Out and No Session
Time out? I checked the IETF at Livingstons Site (pg. 43, 44) and it says
that it should be able to take a 32 bit integer.

Here is an example of the table entries and the resultant radlogin

RadConfigID AccountID RadAttributeID Data Value
1 179 6 2
2 179 8 207.77.56.105
3 179 9 255.255.255.0
4 179 22 207.77.57.16 207.77.56.105 1
5 179 27 43200
6 179 28 43200

Checking Radius user research:
User-Service = Framed-User
Framed-Address = 207.77.56.105
Framed-Netmask = 255.255.255.0
Framed-Route = "207.77.57.16 207.
Session-Timeout = -22336
Idle-Timeout = -22336

Thanks,

Scott