Re: [Emerald] Radlog time out....

Gabe ( (no email) )
Mon, 25 Sep 2000 12:56:25 -0700

You were right about the ports but it still did not change my problem. Any
other ideas?
Gabe
----- Original Message -----
From: "Dale E. Reed Jr." <daler@iea-software.com>
To: <emerald@iea-software.com>
Sent: Monday, September 25, 2000 10:46 AM
Subject: Re: [Emerald] Radlog time out....

> > Gabe wrote:
> >
> > I recently upgraded to SQL 7 on a 2000 server and I am running
> > into problems authenticating from my database via radlogin. I have
> > added the machine to the client list, and I don't want to point our
> > RAS to the server until I can make sure the database is verifying.
> > When I run radlog it stalls and then times out, any ideas??
>
> Radlogin uses the \winnt\system32\drivers\etc\services file to get
> the ports on where to send the requests to. Win2k defaults these
> to the RFC 1812/1813 ports. If you are not using those ports, then
> you need to modify the services file to the ports you are using.
> Otherwise, Radlogin is sending to port 1812, RadiusNT is probably
> listening on 1645, and, well, you get a timeout. :)
>
> --
>
> Dale E. Reed Jr. Emerald and RadiusNT/X
> __________________________________________
> IEA Software, Inc. www.iea-software.com
>
> For more information about this list (including removal) go to:
> http://www.iea-software.com/support/maillists/liststart
>

For more information about this list (including removal) go to: