Josh
From: Clara Hatem <clara@inco.com.lb>
> Yes I have it turned on
>
> Thank you
> Clara
>
> At 10:51 AM 4/14/00 -0400, you wrote:
> >Make sure you have 'Variable login limits' is turned on. Ihad the same
> >problem.
> >
> >-----Original Message-----
> >From: Clara Hatem [mailto:clara@inco.com.lb]
> >Sent: Friday, April 14, 2000 10:32 AM
> >To: radiusnt@iea-software.com
> >Subject: [RadiusNT] MLPPP / RadiusNT / Ascend MAX TNT
> >
> >
> >Hello,
> >
> >We need to offer Multi Link PPP dial up connections to our customers.
> >
> >We are running Emerald, and Radius NT version 2.5.206
> >
> >I have configured the user (clarah) with the following attributes
> >Framed-Protocol = MPP
> >User-Service = Framed-User
> >Idle Timeout = 900 seconds
> >Login Limit = 2
> >
> >I am using DUN on a win95 station with DUN 1.3 Update (to support MLPPP)
> >
> >And establishing a connection to an Ascend MAX TNT Access server.
> >
> >The problem is that the first connection is established , but the second
> >connection drops at authentication. No entries show in the RadLog.
> >
> >We have extracted debug entries from the MAX TNT :
> >(The 2nd MPP session is being authenticated by Radius, but the accounting
> >records are somehow incorrect, triggering the disconnection. I noticed
that
> >accouting record type 0 does not show) ; The username used is clarah.
> >
> >Unsuccessful 2nd MPP Session Attempt
>
>---------------------------------------------------------------------------
> >RADIF: radius type Auth ID = 75
> >RADIF: authenticating <6:clarah> with CHAP
> >RADIF: _radiusRequest: id 75, user name <7:clarah>
> >RADIF: _radiusReq: challenge len = <0>
> >RADIF: _radiusReq: socket 2 len 104 ipaddr 192.168.168.2 port 1678->1645
> >RADIF:_radiusReq: id 75 <7:clarah>, starting timer (10 sec)
> >RADIF: _radCallback: buf=101ECF90 from 192.168.168.2 1645
> >RADIF: _radCallback, authcode = 2, id 75
> >RADIF: _radCallback: id 75, killing timer
> >RADIF: Authentication Ack
> >RADIF: attribute 7, len 6, 00 00 01 00
> >RADIF: attribute 28, len 6, 00 00 03 84
> >RADIF: attribute 6, len 6, 00 00 00 02
> >RADIF: attribute 27, len 6, 2a ae 14 40
> >RADIF:_freeInfoClassSess
> >
> >Accounting Record
>
>---------------------------------------------------------------------------
-
> >
> >RADIF: radius type Acct ID = 72 (<--- Following this there should be a
type
> >0
> > AcctRequest ?? it is missing ...)
> >RADIF: _radiusAcctRequest: type 1 id 72, user name <0:> (<--- Note blank
> >user)
> >RADIF: _radiusAcctReq: socket 4 len 134 IP 194.126.5.8 port 1800=>1646,
> >ID=72
> >RADIF: _radCallback: buf=101EB5D0 from 194.126.5.8 1646
> >RADIF: _radProcAcctRsp: user:<0:>, ID=72
> >RADIF:_freeInfoClassSess
> >RADIF: _radCallback: processed acct server type=1 (<--- Acctg Stop
Record.)
> >
> >
> >
> >Any help is appreciated.
> >
> >Thank you,
> >Clara
For more information about this list (including removal) go to: