RE: [RadiusNT] MLPPP / RadiusNT / Ascend MAX TNT

Clara Hatem ( clara@inco.com.lb )
Tue, 18 Apr 2000 16:05:42 +0200

Yes I have it turned on

Thank you
Clara

At 10:51 AM 4/14/00 -0400, you wrote:
>Make sure you have 'Variable login limits' is turned on. Ihad the same
>problem.
>
>-----Original Message-----
>From: Clara Hatem [mailto:clara@inco.com.lb]
>Sent: Friday, April 14, 2000 10:32 AM
>To: radiusnt@iea-software.com
>Subject: [RadiusNT] MLPPP / RadiusNT / Ascend MAX TNT
>
>
>Hello,
>
>We need to offer Multi Link PPP dial up connections to our customers.
>
>We are running Emerald, and Radius NT version 2.5.206
>
>I have configured the user (clarah) with the following attributes
>Framed-Protocol = MPP
>User-Service = Framed-User
>Idle Timeout = 900 seconds
>Login Limit = 2
>
>I am using DUN on a win95 station with DUN 1.3 Update (to support MLPPP)
>
>And establishing a connection to an Ascend MAX TNT Access server.
>
>The problem is that the first connection is established , but the second
>connection drops at authentication. No entries show in the RadLog.
>
>We have extracted debug entries from the MAX TNT :
>(The 2nd MPP session is being authenticated by Radius, but the accounting
>records are somehow incorrect, triggering the disconnection. I noticed that
>accouting record type 0 does not show) ; The username used is clarah.
>
>Unsuccessful 2nd MPP Session Attempt
>---------------------------------------------------------------------------
>RADIF: radius type Auth ID = 75
>RADIF: authenticating <6:clarah> with CHAP
>RADIF: _radiusRequest: id 75, user name <7:clarah>
>RADIF: _radiusReq: challenge len = <0>
>RADIF: _radiusReq: socket 2 len 104 ipaddr 192.168.168.2 port 1678->1645
>RADIF:_radiusReq: id 75 <7:clarah>, starting timer (10 sec)
>RADIF: _radCallback: buf=101ECF90 from 192.168.168.2 1645
>RADIF: _radCallback, authcode = 2, id 75
>RADIF: _radCallback: id 75, killing timer
>RADIF: Authentication Ack
>RADIF: attribute 7, len 6, 00 00 01 00
>RADIF: attribute 28, len 6, 00 00 03 84
>RADIF: attribute 6, len 6, 00 00 00 02
>RADIF: attribute 27, len 6, 2a ae 14 40
>RADIF:_freeInfoClassSess
>
>Accounting Record
>----------------------------------------------------------------------------
>
>RADIF: radius type Acct ID = 72 (<--- Following this there should be a type
>0
> AcctRequest ?? it is missing ...)
>RADIF: _radiusAcctRequest: type 1 id 72, user name <0:> (<--- Note blank
>user)
>RADIF: _radiusAcctReq: socket 4 len 134 IP 194.126.5.8 port 1800=>1646,
>ID=72
>RADIF: _radCallback: buf=101EB5D0 from 194.126.5.8 1646
>RADIF: _radProcAcctRsp: user:<0:>, ID=72
>RADIF:_freeInfoClassSess
>RADIF: _radCallback: processed acct server type=1 (<--- Acctg Stop Record.)
>
>
>
>Any help is appreciated.
>
>Thank you,
>Clara
>
>
>
>
>
>
>
> `\|||/
> (@@)
> ooO_(_)_Ooo________________________________
> _____|_____|_____|_____|_____|_____|_____|_____|
>___|____|_____|_____|_____|_____|_____|_____|____
>_____|_____|_____|_____Have a Nice Day __|__|____|
>
>Clara Hatem
>Network Operation Center
>
>Technical and IT Dpt.
>IncoNet sal
>Beirut - LEBANON
>
>Mobile: 961 3 278216
>Phone(Office): 961 1 255696 ext 707
>Email:clara@inco.com.lb
>P.O.Box: 16-6928 Beirut - LEBANON
>___|____|_____|_____|_____|_____|_____|_____|____|
>
>
>
>
>
>For more information about this list (including removal) go to:
>http://www.iea-software.com/support/maillists/liststart
>
>For more information about this list (including removal) go to:
>http://www.iea-software.com/support/maillists/liststart
>
>

`\|||/
(@@)
ooO_(_)_Ooo________________________________
_____|_____|_____|_____|_____|_____|_____|_____|
___|____|_____|_____|_____|_____|_____|_____|____
_____|_____|_____|_____Have a Nice Day __|__|____|

Clara Hatem
Beirut - LEBANON

Phone (Home): 961 1 584913
Mobile: 961 3 278216
Phone(Office): 961 1 255696 ext 707
Email: clara@inco.com.lb
P.O.Box: 16-6928 Beirut - LEBANON
___|____|_____|_____|_____|_____|_____|_____|____|