Re: [Emerald] Multilink ISDN

Dale E. Reed Jr. ( (no email) )
Mon, 15 Nov 1999 12:58:04 -0800

> "David V. Brenner" wrote:
>
> Hi, folks. We've just installed our first ISDN (BRI) circuits and I'd
> like to verify that the following RADIUS entries will work in allowing
> callers the following:
>
> 1. Dynamic IP address as per PM2e assigned pool
> 2. Idle time-out of 30 minutes
> 3. Maximum session length of 8 hours
> 4. Single channel or bonded session
>
> Here are the attributes:
>
> User-Service = Framed-User
> Framed-Protocol = MPP

Either PPP or MPP will typically work here.

> Session-Timeout = 28800
> Idle-Timeout = 1800
> NAS-Port-Type = ISDN

You should not send this (the NAS sends this to RadiusNT to tell
RadiusNT what kind of port it is). You might be able to make this
a check attribute to limit them only to calling on the ISDN lines,
though.

> Port-Limit = 2
>
> In MBR -> Services:
>
> Login Limit = 2

-- 

Dale E. Reed Jr. Emerald and RadiusNT__________________________________________IEA Software, Inc. www.iea-software.com

For more information about this list (including removal) go to:http://www.iea-software.com/support/maillists/liststart