Re: [NTISP] Rockwell

Youssef A. Rahman ( (no email) )
Tue, 09 Mar 1999 22:01:34 +0200

customer side..

"(Ken)" wrote:

> is this an init string for the customers modem? or something set on the
> ascend max..
>
> Ken
> -----Original Message-----
> From: Youssef A. Rahman <yrahman@alexcomm.net>
> To: ntisp@iea-software.com <ntisp@iea-software.com>
> Date: Tuesday, March 09, 1999 1:11 PM
> Subject: Re: [NTISP] Rockwell
>
> >We had the same problem with the Ascend Max, and the following
> >initialization string stopped it
> >+ms=k56,1,75,33600,75,5600
> >
> >
> >"Geoffrey L. Scully" wrote:
> >
> >> I am having problems with Rockwell V.90's and most Win Modems with the
> >> 3COM Hiper DSP's. They sit there continuing to handshake and then
> >> eventually timeout. Anyone else having this problem? Anyone figure out
> >> the fix?
> >>