Re: [RadiusNT] VSAs

Dale E. Reed Jr. ( (no email) )
Tue, 02 Nov 1999 18:27:55 -0800

David Sovereen wrote:
>
> Gotta situation here...
>
> We are trying to use the IP Tunnelling feature in our Lucent Portmaster 3s
> to provide content filtering through X-Stop (maybe someone here is familiar
> with the product?) and we want certain connection attributes assigned via
> RadiusNT.
>
> Now, figuring that in the future we might use other features such as NAT and
> the like, I updated all of RadiusNT's attributes and values to that of
> Lucent's Dictionary (maybe a mistake). For VSA's, I now have the following
> (as seen in a -x15 debug):
>
..
> All I want is LE-IPSec-Outsource-Profil = "xstop" The others aren't
> needed. I suppose I could delete them from the dictionary, but I think at
> the root I have a configuration problem. And who knows, I may use other
> VSAs in the future. So I'd really like to find the problem. Any ideas?
> Suggestions?

The problem is most likely your RadGetConfigs and RadGetATConfigs. make
sure they include the RadVendorID and RadVendorType joins. You can see
the full set of them from:

ftp://ftp.iea-software.com/RadiusNT/MSSQL/r25vsa_updt.sql

-- 

Dale E. Reed Jr. Emerald and RadiusNT__________________________________________IEA Software, Inc. www.iea-software.com

For more information about this list (including removal) go to:http://www.iea-software.com/support/maillists/liststart