Re: [RadiusNT] Calls Online

Ray Carpenter ( (no email) )
Fri, 19 Mar 1999 14:33:44 -0500

There was a version of HiperArc code that had this problem but I forget the
version 4.1.5x maybe. I know it works fine with 4.1.72 and should work with
4.1.59. The port numbers are calculated as slot number * 256 (at least with
this version 4.1.72)

Hope this helps
Ray
-----Original Message-----
From: Sam Lowe <slowe@universalcom.net>
To: radiusnt@iea-software.com <radiusnt@iea-software.com>
Date: Friday, March 19, 1999 1:26 PM
Subject: [RadiusNT] Calls Online

>I'm having problems with the calls online table. All the calls in the
calls
>table show up on the same NAS port (1). When I look in the CallsOnline
>table, only the NAS addresses and the ports show up, with no one in them.
>We use Total Controls with Hiper units.
>
>What am I missing.
>
>Thanks.
>
>Samuel S. Lowe
>Director, Data Network Services
>UniversalCom, Inc.
>slowe@universalcom.net
>
>
>
>For more information about this list, including removal, please
>see this URL: http://www.iea-software.com/maillist.html

For more information about this list, including removal, please
see this URL: http://www.iea-software.com/maillist.html