Re: [RadiusNT] port-limit attrib.

Dale E. Reed Jr. ( (no email) )
Thu, 18 Mar 1999 19:54:40 -0800

Stephen Johnson wrote:
>
> The port-limit attribute only affects multi-ppp connections and not ISDN or
> multiple logins of the same account?

Port-Limit only affects the same session bonding multiple channels, like
Multilink-PPP of ISDN, shotgun type modems, etc. It has no affect of
logins of the same name that are not the same session.

> Where would I find the description of what hierarchy the tables take in the
> configuration of users, i.e. I guess I could define the port-limit attribute
> in radatconfigs to be 1 for all ppp accounts but in radconfig, I could
> define a particular user to have a port-limit of 2?

Yes. You could also look at the LoginLimit field, which does
concurrency
and is easier to configuration. RadiusNT checks RadConfigs first, and
if it finds any entries matching the AccountID, it does NOT look at
the RadATConfigs.

> PS About the radius debug -x15 not working, I found in the docs where it
> explains that the debug can't run at the same time as the service.

Yes. You can only have one copy of RadiusNT running at a time.

-- Dale E. Reed Jr.      Emerald and RadiusNT__________________________________________IEA Software, Inc.    www.iea-software.com