Re: [RadiusNT] Vendor specific attributes
Dale E. Reed Jr. ( (no email) )
Sun, 20 Dec 1998 00:29:40 -0800
2Day Chief Enthusiast wrote:
>
> I am running RadiusNT v2.5.124 in ODBC mode with MS SQL server v6.5.
>
> Trying to set reply attribute IP-Output-Filter for a new 3COM Superstack II
> 1500. According to documentation, I need a RadATConfig record with
> RadAttributeID of 26, RadVendorID of 429 and RadVendorType of 36864.
>
> Whenever I insert above, and a client attempts to authenticate, Radius seems
> to want to send a reply for every vendor specific attribute it has an entry
> for in RadAttributes.
>
> What am I doing wrong?
RadiusNT 2.5.124 doesn't have full support for the USR VSAs. You will
need to obtain RadiusNT 2.5.145 (in the hidden /radiusnt/beta directory
on our FTP site) and possibly upgrade your database using the VSa update
script also in that same directory.
-- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com