Re: [RadiusNT] Loging Limit.

Dale E. Reed Jr. ( (no email) )
Thu, 17 Dec 1998 14:20:58 -0800

Carlos Diaz wrote:
>
> Hi there. This is my problem.
> I have users connecting to my system using multilink so i change the
> secction limit to "2" and they connect with the same IP, it work very fine!
> But when the same user try to connect twice using diferents machines he
> can't connect (loging limit error).

In the configuration for the Account Type defaults (RadATConfigs
table) add the Port-Limit=1 attribute. This is a known issue because
newer ISDN equipment does simulataneous dialout and both channels
connect before RadiusNT knows about the other.

-- Dale E. Reed Jr.  (daler@iea-software.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |   http://www.iea-software.com