RE: Ascend Data Filters in Text mode

Dan Meyer ( dmeyer@realcomp.com )
Thu, 22 Oct 1998 10:25:48 -0400

When I do that I get errors reporting an unknown attribute 242 using
radlogin. I believe I need to make some modifications to the dictionary
file, but what are they? Or, I am willing to convert the value to an Ascend
abinary and send it that way. How can i get radiusNT to send that value?

Any help would be appreciated

> -----Original Message-----
> From: Dale E. Reed Jr. [mailto:daler@iea-software.com]
> Sent: Wednesday, October 21, 1998 8:58 PM
> To: Dan Meyer
> Cc: radiusnt@iea-software.com
> Subject: Re: Ascend Data Filters in Text mode
>
>
> Dan Meyer wrote:
> >
> > How would I go about adding Ascend data filters using RadiusNT
> in text mode?
> >
> > I would like to implement a few filters to restrict access to one or two
> > machines here and allow internet. I have the following filters
> I would like
> > to pass.
> >
> > Ascend-Data-Filter = "ip in forward dstip 207.49.236.5/32",
> > Ascend-Data-Filter = "ip in forward dstip 207.49.236.10/32",
> > Ascend-Data-Filter = "ip in forward dstip 207.49.236.13/32",
> > Ascend-Data-Filter = "ip in drop dstip 192.168.254.0/24",
> > Ascend-Data-Filter = "ip in drop dstip 207.49.236.0/24",
> > Ascend-Data-Filter = "ip in forward dstip 0.0.0.0"
> >
> > Or, is it possible to specify a filter set defined on the Maxen?
>
> You would do it just like above. You have to add those to each user
> in your users file.
>
>
> --
> Dale E. Reed Jr. (daler@iea-software.com)
> _________________________________________________________________
> IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs
> Internet Solutions for Today | http://www.iea-software.com
>