Message 1: Re: ServerAccess
from Dale Reed <daler@iea-software.com>

Message 2: Re: Calls table not functioning, Calls online not functioning
from Dale Reed <daler@iea-software.com>

Message 3: USR TCH and MS RRAS (Attribute 32)
from "Mauro J. Jaskelioff" <mauro@citynet.net.ar>

Message 4: Re: ServerAccess
from "Ciro Vera" <cirovera@interaccess.cl>

Message 5: Re: ServerAccess
from "Graeme Slogrove" <graeme@fdd.net>

Message 6: Re: ServerAccess
from "Ciro Vera" <cirovera@interaccess.cl>

Message 7: Re: USR TCH and MS RRAS (Attribute 32)
from Dale Reed <daler@iea-software.com>

Message 8: Re: USR TCH and MS RRAS (Attribute 32)
from "Mauro J. Jaskelioff" <mauro@citynet.net.ar>

Message 9: unsubscribe
from "Petter Norberg" <petter@bip.net>

Message 10: unsubscribe
from "Doris Dean" <doris@bc-alter.net>

Message 11: Re: Calls table not functioning, Calls online not functioning
from "James B. Hrdy" <jhrdy@greensoft.com>

Message 12: Re: USR TCH and MS RRAS (Attribute 32)
from Dale Reed <daler@iea-software.com>

Message 13: Re: Calls table not functioning, Calls online not functioning
from Dale Reed <daler@iea-software.com>

Message 14: Re: Calls table not functioning, Calls online not functioning
from Carl Jagerski <carll@forcomm.net>

Message 15: Re: Calls table not functioning, Calls online not functioning
from Dale Reed <daler@iea-software.com>

Message 16: Dictionary
from "webmaster" <webmaster@skyquest.net>

Message 17: Re: Dictionary
from Dale Reed <daler@iea-software.com>

..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.
| Message 1 |
'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'
Subject: Re: ServerAccess
From: Dale Reed <daler@iea-software.com>
Date: Wed, 24 Jun 1998 01:35:52 -0700

Ciro Vera wrote:
>
> Current time is 1045 (minutes past midnight ), and StartTime=0,
> StopTime=100 then
> I think that a PPP user is allowed to login only between Starttime and
> Stoptime,
> but at current Time the authentification is done and PPP users is
> allowed to login :(

Both Start/Stop must be non-null and non-zero. Change the starttime
to 1 and it should reject the auth.

-- Dale E. Reed Jr.  (daler@iea-software.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |   http://www.iea-software.com

..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 2 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: Calls table not functioning, Calls online not functioningFrom: Dale Reed <daler@iea-software.com>Date: Wed, 24 Jun 1998 01:55:46 -0700

James B. Hrdy wrote:> > Here is the debug info from a different install of RadiusNT, but with a> similar problem. The calls online isnt working.> > ODBC Error:23000:-1605:> [Microsoft][ODBC Microsoft Access 97 Driver] The changes you requested to the table> were not successful because they would create duplicate values in the index, primary key,> or relationship. Change the data in the field or fields that contain duplicate data, remove> the index, or redefine the index to permit duplicate entries and try again.

This error usually means that RadiusNT already received the accountingrequest. I have had reports of upgrading the OS of a USR and itresetting the Acct-Session-ID counter, which caused all the duplicatesfor a long time. If you are seeing this, you can update all theAcct-Session-ID fields in your DB like:

Update CallsSet AcctSessionID = '99' + AcctSessionID

-- Dale E. Reed Jr.  (daler@iea-software.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |   http://www.iea-software.com

..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 3 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: USR TCH and MS RRAS (Attribute 32)From: "Mauro J. Jaskelioff" <mauro@citynet.net.ar>Date: Wed, 24 Jun 1998 12:07:25

I=B4m using RadiusNT 2.5, a USR Total Control Hub and Microsoft RRAS as= NASs.I had a problem because the TCH is sending the Attribute 4 and 32, theninsert into calls would say "duplicate NAS-Identifier", i renamed Att 32 toNAS-Identifier2 to fix this problem. But Mirsoft RRAS is sending only theAttr 32, so when RadiusNT tries to insert a record into the calls table itsays "Nas-Identifier cannot be NULL".How do I fix this problem?************************* Mauro J. Jaskelioff ** mauro@citynet.net.ar ** Depto T=E9cnico ** Citynet S.A. *************************

..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 4 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: ServerAccessFrom: "Ciro Vera" <cirovera@interaccess.cl>Date: Wed, 24 Jun 1998 11:45:39 -0000

This is a multi-part message in MIME format.

------=_NextPart_000_01BD9F65.9C124C00Content-Type: text/plain; charset=ISO-8859-1Content-Transfer-Encoding: 8bit

Dale, I Change the startTime to 1 but radiusnt no reject the auth :(

----------> From: Dale Reed <daler@iea-software.com>> To: radiusnt@iea-software.com> Subject: Re: ServerAccess> Date: Miércoles 24 de Junio de 1998 03:35 AM> > Ciro Vera wrote:> > > > Current time is 1045 (minutes past midnight ), and StartTime=0,> > StopTime=100 then> > I think that a PPP user is allowed to login only between Starttime and> > Stoptime,> > but at current Time the authentification is done and PPP users is> > allowed to login :(> > Both Start/Stop must be non-null and non-zero. Change the starttime> to 1 and it should reject the auth.> > -- > Dale E. Reed Jr. (daler@iea-software.com)> _________________________________________________________________> IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs> Internet Solutions for Today | http://www.iea-software.com------=_NextPart_000_01BD9F65.9C124C00Content-Type: text/html; charset=ISO-8859-1Content-Transfer-Encoding: quoted-printable

Dale,
I Change the startTime to 1 =but radiusnt no reject the auth :(

----------
> From: Dale =Reed <daler@iea-software.com>
> To: radiusnt@iea-software.com
> Subject: Re: ServerAccess
> Date: =Mi=E9rcoles 24 de Junio de 1998 03:35 AM
>
> Ciro Vera =wrote:
> >
> > Current time is 1045 (minutes past =midnight ), and StartTime=3D0,
> > StopTime=3D100 then
> => I think that a PPP user is allowed to login only between Starttime =and
> > Stoptime,
> > but at current Time  the =authentification is done and PPP users is
> > allowed to login =:(
>
> Both Start/Stop must be non-null and non-zero. = Change the starttime
> to 1 and it should reject the =auth.
>  
> --
> Dale E. Reed Jr.  (daler@iea-software.com)
> =_________________________________________________________________
>=        IEA Software, Inc. =     |  RadiusNT, Emerald, and NT =FAQs
>  Internet Solutions for Today  | =  http://www.iea-software.com

------=_NextPart_000_01BD9F65.9C124C00--..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 5 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: ServerAccessFrom: "Graeme Slogrove" Date: Wed, 24 Jun 1998 17:51:54 +0200On 24 Jun 98 at 11:45, Ciro Vera wrote:> I Change the startTime to 1 but radiusnt no reject the auth :(Have you got serveraccess enabled in the radius admin ?Regards, Graeme---Graeme Slogrove, BSc (Eng) Elec (Wits)FastLight Data Distribution cchttp://www.fdd.netTel: +27-(0)11-706-0212 Fax: +27-(0)11-706-0812..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 6 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: ServerAccessFrom: "Ciro Vera" Date: Wed, 24 Jun 1998 12:10:45 -0000This is a multi-part message in MIME format.------=_NextPart_000_01BD9F69.1D8611B0Content-Type: text/plain; charset=ISO-8859-1Content-Transfer-Encoding: 8bitYes, of course----------> From: Graeme Slogrove > To: radiusnt@iea-software.com> Subject: Re: ServerAccess> Date: Miércoles 24 de Junio de 1998 10:51 AM> > On 24 Jun 98 at 11:45, Ciro Vera wrote:> > > I Change the startTime to 1 but radiusnt no reject the auth :(> > Have you got serveraccess enabled in the radius admin ?> > > Regards,> Graeme> > ---> Graeme Slogrove, BSc (Eng) Elec (Wits)> FastLight Data Distribution cc> http://www.fdd.net> Tel: +27-(0)11-706-0212 Fax: +27-(0)11-706-0812------=_NextPart_000_01BD9F69.1D8611B0Content-Type: text/html; charset=ISO-8859-1Content-Transfer-Encoding: quoted-printable

Yes, of =course

----------
> From: Graeme Slogrove <graeme@fdd.net>
> To: radiusnt@iea-software.com
> Subject: Re: ServerAccess
> Date: =Mi=E9rcoles 24 de Junio de 1998 10:51 AM
>
> On 24 Jun 98 =at 11:45, Ciro Vera wrote:
>
> > I Change the startTime =to 1 but radiusnt no reject the auth :(
>
> Have you got =serveraccess enabled in the radius admin ?
>
>
> =Regards,
>   Graeme
>
> ---
> Graeme =Slogrove, BSc (Eng) Elec (Wits)
> FastLight Data Distribution =cc
> http://www.fdd.net
> Tel: +27-(0)11-706-0212   Fax: =+27-(0)11-706-0812

------=_NextPart_000_01BD9F69.1D8611B0--..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 7 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: USR TCH and MS RRAS (Attribute 32)From: Dale Reed Date: Wed, 24 Jun 1998 10:15:25 -0700Mauro J. Jaskelioff wrote:> > I´m using RadiusNT 2.5, a USR Total Control Hub and Microsoft RRAS as NASs.> I had a problem because the TCH is sending the Attribute 4 and 32, then> insert into calls would say "duplicate NAS-Identifier", i renamed Att 32 to> NAS-Identifier2 to fix this problem. But Mirsoft RRAS is sending only the> Attr 32, so when RadiusNT tries to insert a record into the calls table it> says "Nas-Identifier cannot be NULL".> How do I fix this problem?Name #32 to NAS-Identifier and #4 to NAS-IP-Address. Create twoentries in the Servers table for each tc or RRAS, one with an IP matching #32 (used for on-line/concurrency) and another with an IPmatching the actuall IP address (used to validate the request).-- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 8 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: USR TCH and MS RRAS (Attribute 32)From: "Mauro J. Jaskelioff" Date: Wed, 24 Jun 1998 15:58:40Which entrie is used with the serveraccess Table? (#32 or #4)At 10:15 AM 6/24/98 -0700, you wrote:>Mauro J. Jaskelioff wrote:>>=20>> I=B4m using RadiusNT 2.5, a USR Total Control Hub and Microsoft RRAS as= NASs.>> I had a problem because the TCH is sending the Attribute 4 and 32, then>> insert into calls would say "duplicate NAS-Identifier", i renamed Att 32= to>> NAS-Identifier2 to fix this problem. But Mirsoft RRAS is sending only the>> Attr 32, so when RadiusNT tries to insert a record into the calls table= it>> says "Nas-Identifier cannot be NULL".>> How do I fix this problem?>>Name #32 to NAS-Identifier and #4 to NAS-IP-Address. Create two>entries in the Servers table for each tc or RRAS, one with an IP=20>matching #32 (used for on-line/concurrency) and another with an IP>matching the actuall IP address (used to validate the request).>>--=20>Dale E. Reed Jr. (daler@iea-software.com)>_________________________________________________________________> IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs> Internet Solutions for Today | http://www.iea-software.com>>************************* Mauro J. Jaskelioff ** mauro@citynet.net.ar ** Depto T=E9cnico ** Citynet S.A. *************************..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 9 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: unsubscribeFrom: "Petter Norberg" Date: Tue, 24 Jun 1997 21:49:21 +0200unsubscribe..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 10 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: unsubscribeFrom: "Doris Dean" Date: Wed, 24 Jun 1998 13:10:52 -0700unsubscribe..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 11 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: Calls table not functioning, Calls online not functioningFrom: "James B. Hrdy" Date: Wed, 24 Jun 1998 15:32:14 +0000Is this possible with an Access database?> James B. Hrdy wrote:> > > > Here is the debug info from a different install of RadiusNT, but with a> > similar problem. The calls online isnt working.> > > > ODBC Error:23000:-1605:> > [Microsoft][ODBC Microsoft Access 97 Driver] The changes you requested to the> > table were not successful because they would create duplicate values in the> > index, primary key, or relationship. Change the data in the field or fields> > that contain duplicate data, remove the index, or redefine the index to permit> > duplicate entries and try again.> > This error usually means that RadiusNT already received the accounting> request. I have had reports of upgrading the OS of a USR and it> resetting the Acct-Session-ID counter, which caused all the duplicates> for a long time. If you are seeing this, you can update all the> Acct-Session-ID fields in your DB like:> > Update Calls> Set AcctSessionID = '99' + AcctSessionID> > -- Dale E. Reed Jr. > (daler@iea-software.com)________________________________________________________> _________ IEA SoftwarJames B. Hrdyemail: jhrdy@greensoft.comweb: http://www.greensoft.com/billingGreenSoft Solutions, Inc.Voice: 785.843.8683 ext 2032317 Ponderosa DriveFax: 785.840.0055Lawrence, Ks.United States of America..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 12 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: USR TCH and MS RRAS (Attribute 32)From: Dale Reed Date: Wed, 24 Jun 1998 13:43:14 -0700Mauro J. Jaskelioff wrote:> > Which entrie is used with the serveraccess Table? (#32 or #4)Which ever one is named NAS-Identifier. -- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 13 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: Calls table not functioning, Calls online not functioningFrom: Dale Reed Date: Wed, 24 Jun 1998 14:04:45 -0700James B. Hrdy wrote:> > Is this possible with an Access database?Yes. Just type that as an update query.-- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 14 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: Calls table not functioning, Calls online not functioningFrom: Carl Jagerski Date: Wed, 24 Jun 1998 17:05:08 -0400What if the calls file is empty to start with???That the same problem but the calls file is empty to start with.At 03:32 PM 6/24/98 +0000, you wrote:>Is this possible with an Access database?>>>> James B. Hrdy wrote:>> > >> > Here is the debug info from a different install of RadiusNT, but with a>> > similar problem. The calls online isnt working.>> > >> > ODBC Error:23000:-1605:>> > [Microsoft][ODBC Microsoft Access 97 Driver] The changes you requestedto the>> > table were not successful because they would create duplicate valuesin the>> > index, primary key, or relationship. Change the data in the field orfields>> > that contain duplicate data, remove the index, or redefine the indexto permit>> > duplicate entries and try again.>> >> This error usually means that RadiusNT already received the accounting>> request. I have had reports of upgrading the OS of a USR and it>> resetting the Acct-Session-ID counter, which caused all the duplicates>> for a long time. If you are seeing this, you can update all the>> Acct-Session-ID fields in your DB like:>> >> Update Calls>> Set AcctSessionID = '99' + AcctSessionID>> >> -- Dale E. Reed Jr. >>(daler@iea-software.com)________________________________________________________>> _________ IEA Softwar>>>James B. Hrdy>email: jhrdy@greensoft.com>web: http://www.greensoft.com/billing>GreenSoft Solutions, Inc.>Voice: 785.843.8683 ext 203>2317 Ponderosa Drive>Fax: 785.840.0055>Lawrence, Ks.>United States of America>>Carl JagerskiNetwork Administrator, Forward Communicationscarll@forcomm.net412-378-4490 Fax: 412-375-0156..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 15 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: Calls table not functioning, Calls online not functioningFrom: Dale Reed Date: Wed, 24 Jun 1998 17:42:36 -0700Carl Jagerski wrote:> > What if the calls file is empty to start with???> That the same problem but the calls file is empty to start with.If the Calls table was empty, it wouldn't be complaining about aduplicate key, because there would be no keys. :) -- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 16 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: DictionaryFrom: "webmaster" Date: Wed, 24 Jun 1998 23:49:07 -0400I have not found much information about the dictionary file. We use anAscend MAX4048 and they have a dictionary file at their FTP site. Wouldthis file from Ascend be better suited for our hardware than your commonone? Also, are there any more examples like the users.example file to getmore ideas on how to configure accounts, or can any/all of the parameterslisted in the dictionary file be used in configuring accounts?..------ ------ ------ ------ ------ ------ ------ ------ ------ ------.| Message 17 |'------ ------ ------ ------ ------ ------ ------ ------ ------ ------'Subject: Re: DictionaryFrom: Dale Reed Date: Wed, 24 Jun 1998 21:18:39 -0700webmaster wrote:> > I have not found much information about the dictionary file. We use an> Ascend MAX4048 and they have a dictionary file at their FTP site. Would> this file from Ascend be better suited for our hardware than your common> one? Also, are there any more examples like the users.example file to get> more ideas on how to configure accounts, or can any/all of the parameters> listed in the dictionary file be used in configuring accounts?I would recommend reading the Ascend RADIUS supplementary docuentation.It includes dictionary information, example users file, etc.-- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com