Re: USR TCH and MS RRAS (Attribute 32)
Dale Reed ( daler@iea-software.com )
Wed, 24 Jun 1998 10:15:25 -0700
Mauro J. Jaskelioff wrote:
>
> I´m using RadiusNT 2.5, a USR Total Control Hub and Microsoft RRAS as NASs.
> I had a problem because the TCH is sending the Attribute 4 and 32, then
> insert into calls would say "duplicate NAS-Identifier", i renamed Att 32 to
> NAS-Identifier2 to fix this problem. But Mirsoft RRAS is sending only the
> Attr 32, so when RadiusNT tries to insert a record into the calls table it
> says "Nas-Identifier cannot be NULL".
> How do I fix this problem?
Name #32 to NAS-Identifier and #4 to NAS-IP-Address. Create two
entries in the Servers table for each tc or RRAS, one with an IP
matching #32 (used for on-line/concurrency) and another with an IP
matching the actuall IP address (used to validate the request).
-- Dale E. Reed Jr. (daler@iea-software.com)_________________________________________________________________ IEA Software, Inc. | RadiusNT, Emerald, and NT FAQs Internet Solutions for Today | http://www.iea-software.com