Re: static IP and AS5200 problem

Dale E. Reed Jr. ( (no email) )
Fri, 05 Jun 1998 15:28:28 -0700

Christian Simard wrote:
>
> thank you it works! Now I have another problem...
>
> When I connect to my CISCO AS5200, I can specify any
> IP address in the win 95 dialup networking and It will be accepted!!
> this should never happen with dynamic assigned IP address!!!
> I have not this problem with my old plain text Livingston radius

Make sure the Framed-Address protocol is 255.255.255.254. If
its set to 255.255.255.255, then its negotiated and they can pick
their own (really bad).

> I use radiusnt 1.16 with ODBC (SQL Server)

I would highly recommend upgraded to RadiusNT 2.5.

-- Dale E. Reed Jr.  (daler@iea-software.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |   http://www.iea-software.com