Re: Access ODBC Errors

Dale E. Reed Jr. ( (no email) )
Fri, 08 May 1998 20:40:44 -0700

Tony wrote:
>
> We are getting errors authenicating to an Access database w/portmaster2
> here is the Debug.
> We removed the primary keys in the Calls Table and it started to work,
> But we are looking for the real reason/cure for this problem
>
> radrecv: Request from host a835b404 code=4, id=2, length=90
> Acct-Session-Id = "7B000000"
> User-Name = "tony"
> NAS-IP-Address = 168.53.180.4
> NAS-Port = 0
> NAS-Port-Type = Async
> Acct-Status-Type = Start
> Acct-Authentic = RADIUS
> User-Service = Framed-User
> Framed-Protocol = PPP
> Framed-Address = 168.53.180.10
> Acct-Delay-Time = 843

Rename Attribure #4 in your dictionary from NAS-IP-Address to
NAS-Identifier and restart RadiusNT. That will fix the problem.

-- Dale E. Reed Jr.  (daler@iea-software.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |   http://www.iea-software.com