About 2 weeks ago we had a modem on one of our USR Total Control Card =
stop
working. USR had me reset the card in the chassis. Since this the =
On-Line
tab of emerald has not properly updated any of the port on that card =
(ports
5-8). I ran the calltrig SQL script under ftp://<iea>Emerald/SQL but =
that
did not help. I've gone into Administrator and toggle the online status =
of
these ports. Didn't work. I've even gone into the server_ports table =
and
tried to set the proper info for the time.
How did re-seating the card cause the On-Line calls to stop updating
properly, and what should I do to fix it.
Note: Ports 9 on seem to function ok.
I think for some reason the Account-Session-ID was reset and now it =
won't insert into the calls table because of a duplicate key!