More Newbie Questions

Richard Wong ( rwong@starcon.com )
Wed, 17 Dec 1997 16:56:40 -0800

Greetings:

I'm trying to learn how RadiusNT works. Right no I'm testing it with a
Gandalf Expressway RLAN NAS. I will be using a Cisco AS5300 in the new
year. When I dial into the Gandalf with an analog modem using Win95 DUN, I
get the following response at my RadiusNT server:

----------
radrecv: Request from host cfe6f409 code=1, id=2, length=69
User-Name = "test"
Challenge-Response = "\036\302\234\014\033\247"
NAS-IP-Address = 207.230.244.9
NAS-Port = 71
NAS-Port-Type = Async
CHAP-Challenge = "\211 \034\367"
rad_authenticate()
Checking user record PW_PASSWORD type
authChapPwd
Sending Reject of id 2 to cfe6f409 (207.230.244.9)

Resp Time: 252 Auth: 1/2 -> 3 Acct: 0/0/0 -> 0
----------

The connection is rejected. My test user file looks as follows:

User File:
=========
test Password = "test"
User-Service = Framed-User,
Framed-Protocol = PPP,
Framed-Address = 255.255.255.254

I am currently running RasdiusNT 2.2 as it came. I've got RadiusNT running
on a Win95 system right now and have been able to test it with 'radlogin'
successfully. I've set RadiusNT up in the text mode right now without ODBC
for my current tests.

What am I doing wrong?

tia,

RW