I am curently running the current version on an NT backup domain controller,
using a Livingston Portmaster 3. When I enter the username and password in
the users file, then logging on works, but using DEFAULT and "WINNT", i get
the following debug output;
C:\radius>radius -x15
RadiusNT 1.16.60 2/7/97 Copyright (c) 1996 IEA Software, Inc.
All Rights Reserved, Worldwide
Some portions Copyright (c) 1992 Livingston Enterprises, Inc.
and Copyright (c) 1995 Ascend Communications, Inc.
Param: Debug Level: 15
Initializing Winsock...
Client:208.132.114.80:208.132.114.80:jenny14
config_init(): dict_valfind(Lifetime-In-Days) not found.
Loading users...
User:DEFAULT
1 users loaded!
Radius NT is ready to receive requests!
radrecv: Request from host d0847250 code=1, id=105, length=79
User-Name = "username"
Password = "E\326\371\210{\3017\235\357)N\264\333\3471\230"
NAS-IP-Address = 208.132.114.80
NAS-Port = 0
NAS-Port-Type = Async
Service-Type = Framed-User
Framed-Protocol = PPP
rad_authenticate()
Checking user record PW_PASSWORD type
authPapPwd
chkPwd->strvalue is WINNT
decrypted pwd is password
Sending Reject of id 105 to d0847250 (208.132.114.80)
Response Time: 240
The following are my config files
clients
#Client Name Key
#---------------- -------------------
208.132.114.80 jenny14
users
DEFAULT Password = "WINNT"
User-Service = Framed-User,
Framed-Protocol = PPP,
Also, should the dictionary file be changed to the Livingston dictionary?
I'd sincerely appreciate any help you might have to offer. Thanks.
David Glynn
dglynn@rr1.net