RE: RE: RE: NT Install Question.

ronb@SYSYGY.com.au
Fri, 30 May 1997 08:45:36 +1000

Unfortunately not.

Cheers,
Ron.

> -----Original Message-----
> From: Matthew Andersen [SMTP:mander@loginet.com]
> Sent: Friday, May 30, 1997 8:34 AM
> To: 'ntisp@emerald.iea.com'
> Subject: RE: RE: NT Install Question.
>
> This isn't possible. The server is about 2000 miles away. And
> bringing the other machine too it is not a possibility. So there is
> no way to do this?
> Thanks,
> Matthew
>
> ----------
> From: ronb@SYSYGY.com.au
> Sent: 5/29/97 3:23:41 PM
> To: ntisp@emerald.iea.com
> CC:
> Subject: RE: NT Install Question.
>
> The BDC must be connected to the PDC at the time of its
> installation.
> Once it's configured as a BDC, then you can move it away, and get it
> to
> act over a RAS link.
>
> Cheers,
> Ron.
>
>
> > -----Original Message-----
> > From: Matthew Andersen [SMTP:mander@loginet.com]
> > Sent: Friday, May 30, 1997 7:04 AM
> > To: 'ntisp@emerald.iea.com'
> > Subject: NT Install Question.
> >
> > I am trying to setup a BDC over a RAS link, but when I install NT it
> > won't give me the chance to dial in and get authenticated by the
> PDC.
> > Anyone know how to set this up?
> > Thanks,
> > Matthew
> > mander@loginet.com
> >
>
> ----------------------------------------------------------
> NTISP Mailing List listserver@emerald.iea.com
>
>