James T. Robson wrote:
>
> > Radius will now boot ok and load the users from the users file, but they
> > cannot logon. They get a message about not being able to negotiate an
> > appropriate protocol.
> >
> > If I try to do ODBC I get the following. This is when I set RadAdmin to
> > read an Access 7.0 file and point it to the radius7.mdb file. Have you
> > seen this before? Dale??

What does RadiusNT show in -x15 debug mode for the authentication
request?
This is the most important thing to look at and post when you are having
problems.

> > 7) DataDirectory: ../radius
> > 8) AcctDirectory: ..radius/acct

You probably want to change these in the RadiusNT Administrator.

> > ODBC: SQLConnect Error: [Microsoft][ODBC Driver Manager] Driver's
> > SQLSetConnectOption failed

This is probably the interesting one. I finally duplicated it by
creating
an ODBC DSN which pointed to an Access database that didn't exist.
Doublt
check your ODBC DSN and make sure you have specified the database
correctly.

-- Dale E. Reed Jr.  (daler@iea.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |    http://www.emerald.iea.com