Re: Setting up max time on line

Dale E. Reed Jr. ( (no email) )
Tue, 01 Apr 1997 12:55:13 -0800

Walter Ray wrote:
>
> I'm using the Livingston PM2E protmaster and Radius NT. I would like to
> find out the best was to set up a max online time for callers. We seem
> to have some callers that are using the system for a "dedicated connection"
> and leving themselves logged on for 12+ hours at a time. I need to find a
> way to automatically cut them off after a specified time limit. They can
> call back and relog on but I don't want them to be able to keep the connection
> open for ever. Is there a function in Radius that will do this?

Just add a Session-Timeout attribute to the user's PPP account Type.
Its in seconds, so like 7200 wouldbe two hours, etc.

-- Dale E. Reed Jr.  (daler@iea.com)_________________________________________________________________       IEA Software, Inc.      |  RadiusNT, Emerald, and NT FAQs Internet Solutions for Today  |    http://www.emerald.iea.com