RE: [RadiusNT] Radlogin problems

Graeme Slogrove ( Graeme@na.co.za )
Wed, 19 Apr 2000 21:11:14 +0200

If you mean debug from RadiusNT, I don't know - it's running as a service.
Radlogin simply waits for a couple of seconds and then shows a T/O : 1 (1
timeout)

Regards,
Graeme

---Graeme Slogrove, BSc (Eng) Elec (Wits)Director, Systems Development & Value Added ServicesNetActive InternetTel: 011-719-0333    Fax: 011-719-0444Support: 011-719-0300

-----Original Message-----From: dsmith@kleintech.com [mailto:dsmith@kleintech.com]Sent: 19 April 2000 07:43To: Graeme SlogroveSubject: RE: [RadiusNT] Radlogin problems

Do you have any debug information showing up?

Graeme Slogrove <Graeme@na.co.za> on 04/19/2000 10:59:06 AM

To: David L Smith/Klein@KLEIN cc: radiusnt@iea-software.com Subject: RE: [RadiusNT] Radlogin problems

It is named "server", I have the entry in it for 127.0.0.1 and I also havean entry in the servers table.

Regards,Graeme

---Graeme Slogrove, BSc (Eng) Elec (Wits)Director, Systems Development & Value Added ServicesNetActive InternetTel: 011-719-0333    Fax: 011-719-0444Support: 011-719-0300

-----Original Message-----From: dsmith@kleintech.com [mailto:dsmith@kleintech.com]Sent: 19 April 2000 04:26To: radiusnt@iea-software.comSubject: RE: [RadiusNT] Radlogin problems

In your original email you mention the file "servers". This file nameshould be"server" (no 's' on the end). That's one thing.

If your running text mode - make sure you have the 127.0.0.1 entry in theclients file.If your running an ODBC connection to a database, I believe you need thesameentry in the Servers table.

That's all I can see that would perhaps cause the problem...

Graeme Slogrove <Graeme@na.co.za> on 04/19/2000 09:18:54 AM

Please respond to radiusnt@iea-software.com

To: radiusnt@iea-software.com

cc: (bcc: David L Smith/Klein)

Subject: RE: [RadiusNT] Radlogin problems

It's running on 1645.

Regards,Graeme

---Graeme Slogrove, BSc (Eng) Elec (Wits)Director, Systems Development & Value Added ServicesNetActive InternetTel: 011-719-0333    Fax: 011-719-0444Support: 011-719-0300

-----Original Message-----From: dsmith@kleintech.com [mailto:dsmith@kleintech.com]Sent: 19 April 2000 03:13To: radiusnt@iea-software.comSubject: Re: [RadiusNT] Radlogin problems

If your not using the default radius port 1645 and are configured to use1812,you need to modify your services file.add the lineradius 1812/udp

For more information about this list (including removal) go to:http://www.iea-software.com/support/maillists/liststart